THE TWIN POWER PACK
Renner Screw Compressors
Ranging from 75 to 110 kW
7.5 to 15 bar |
 |
| With the RS-T series RENNER has expanded its
production range specifically in the sector for higher performance. |
 |
| A great number of the RENNER construction
features have also been implemented here. Completely new, however,
is the basic concept that is oriented completely towards operational
safety and efficiency, i.e. for the benefit of the user. |
 |
| The system consists in each case
of identical twin compressors, separate drive motors and separate
coolers, enclosed in a noise insulated cabinet. |
 |
| The advantages of this type of
design are obvious: |
 |
 |
Highest possible operational safety. |
 |
The air supply does not depend on one compressor, this
is also true for motors, coolers and other components.
|
 |
Should one compressor stand still, the performance of
the other is always at the ready. |
 |
The intelligent control guarantees efficient
operation. Both compressors have a "soft" start-up,
i.e. peak current values are minimised. |
 |
During operation the system adapts its self to the air
requirement with only one compressor running during low
air demand periods. |
 |
The lead unit is automatically changed over, thus ensuring
optimum duty of both units. |
 |
|
|
| 
|
| Cost distribution for
compressed air production: |
 |
 |
 |
 |
|
|
| Technical
data |
 |
 |
 |
 |
 |
 |
 |
 |
 |
| Type |
|
00 |
|
|
 |
 |
 |
| RS-T |
75 |
|
| RS-T |
90 |
| RS-T |
110 |
|
 |
free
air deliveredf.a.d.
m3/min at |
| 7,5 bar |
10 bar |
13 bar |
15 bar |
|
| |
|
|
|
 |
| 12,30 |
10,48 |
9,12 |
8,30 |
|
| 14,50 |
13,02 |
11,10 |
10,06 |
| 18,60 |
15,92 |
13,40 |
11,74 |
|
 |
| motor
power |
| kW |
HP |
|
|
| 2 x 37 |
2 x 50 |
| 2 x 45 |
2 x 60 |
| 2 x 55 |
2 x 75 |
|
 |
| dimensions |
| width
x depth x height in mm |
|
| 2020
x 1500 x 2080 |
| 2020
x 1500 x 2080 |
| in preparation |
|
 |
|
 |
 |
 |
 |
 |
 |
 |
 |
 |
|
|
|
| |
|
| |
|
| |
|
| |
|
|
|